OceanProAquatics - Aquatic Contractors
Fish, Coral & Other Live Stock
Aquarium Products
Gift Certificates
Mega Savings
  Top » Catalog » Aquarium Products » Filters » UV Sterilizers » UV Parts & Accessories » R175072 My Account  |  Cart Contents  |  Checkout   
   Categories
Fish, Coral & Other Live Stock->
Aquarium Products->
  Additives & Supplements
  Air Pumps
  Algae & Greenwater Solutions
  Aquariums & Accessories->
  Artificial Corals->
  Chillers->
  Extreme Gadgets
  Filter Media
  Filters->
    Canister Filters
    Filter Parts
    Inline/Specialty Filters
    Internal Filters
    Overflow Boxes
    UV Sterilizers->
    Wet/Dry Systems
  Food - Marine, Reef, Fresh & Koi->
  Heaters
  Lighting->
  Maintenance Equipment->
  Medications
  Monitors and Controllers->
  Reactors->
  Reef Farming & Educational Tools
  Skimmers->
  Water Pumps->
  Water Treatments
  Wavemakers
  Hard to find Parts & Accessories
Gift Certificates
Mega Savings->
    Manufacturers  Manufacturers
   Online Chat
   Newsletter
   What's New?  more
 TANK RAISED - SNOWFLAKE Percula Clownfish (Adult Breeders)
TANK RAISED - SNOWFLAKE Percula Clownfish (Adult Breeders)
$249.00
$99.00
   Free Stuff
   Information
Auction Listings
Shipping & Returns
Privacy Notice
Store Knowledge Base
Contact Us
Order Tracking
Downloadable catalog
Printable Catalog
Gift Voucher FAQ
   Apply Now




   Online Help
   Currencies
UV Replacement Gasket(SHIPS FREE)
[R175072]
$3.42

 

SHIPS FREE FOR A LIMITED TIME

 

LIFEGARD #R175072
RAINTIGHT REPLACEMENT GASKET
FOR LIFEGARD ULTRAVIOLET STERILIZERS

 

The Lifegard Raintight Coupling keeps moisture out of the UV Sterilizer and protects the bulb from moisture damage. It will keep electrical connection dry and allow safe operation when unit is installed outdoors. Please note that the ballast assembly must also be kept dry, with no chance for water contact. Water contact will damage ballast and possibly create an electrical hazard. Please see Raintight Ballast Box instructions on other side.
 RAINTIGHT COUPLING INSTALLATION INSTRUCTIONS
 1. Turn off pump.
 2. Shut off ball valves located on each side of UV Sterilizer.
 3. Unplug ballast assembly that operates UV bulb.
 4. Remove bulb with ballast attached from unit by pulling assembly straight out.
 5. Squeeze the narrow end of the splash boot in one hand and with the cord in the other hand gently work the pin connectors towards the large open end of the splash boot. This will force the electrical connection out of the splash boot. Separate the bulb from the 4-pin female connector by pulling the two connectors apart. Do not pull the wires as this will damage the bulb and/or the female connector. Set the ballast and bulb aside.
 6. Unscrew the cap with quartz sleeve attached.
 7. Unscrew the compression coupling on top of the cap and discard. The gasket must remain entirely below open end of quartz sleeve to achieve and maintain a positive seal.
 8. Screw the bottom of the Raintight Coupling onto the cap thread. The compression coupling will push the quartz sleeve and gasket into proper position as you hand tighten. Tighten until sleeve and cap are secured together.
 9. Carefully insert quartz sleeve with cap attached into center of UV Sterilizer and hand tighten.
 10. Unscrew the top cap of the Raintight Coupling and remove the split gasket.
 11. Separate bulb from 4-pin connector on ballast. Slide the splash boot up the ballast cord and away from the 4-pin female connector.
 12. Insert the 4-pin female connector through the top cap of the Raintight Coupling.
 13. The clear wire covering should touch the 4-pin connector so that individual wires are not exposed. If wires are exposed, pull clear covering towards 4-pin connector before installing gasket. Do not pull on 4-pin connector or wires. Open the split gasket and slide gasket over clear wire covering above the 4-pin female connector. Be certain split gasket is positioned over clear wire covering and not on the individual wires, to achieve proper seal.
 14. Match the pins of the male bulb and female connector and push into place.
 15. Gently insert bulb through Raintight Coupling on top of UV Sterilizer until it reaches the bottom of the quartz sleeve inside the unit.
 16. Slide top cap of Raintight Coupling over split gasket and tighten onto top thread of the Coupling. Hand tighten only.
 17. The splash boot is no longer necessary. It can be placed over the Raintight Coupling if desired or can be cut off. Use caution not to cut ballast wires.

Part # Description
R175071 Raintight Coupling with Gasket
R175072 Replacement Gasket

 

 

 

For more information, please visit this products webpage.
This product was added to our catalog on Tuesday 10 July, 2007.
    Reviews
   Shopping Cart  more
0 items
   Secure Checkout
Learn about our Secure Online Checkout
   Manufacturer Info
 Lifegard Aquatics
Lifegard Aquatics Homepage
Other products
   Notifications  more
 Notifications  Notify me of updates to UV Replacement Gasket(SHIPS FREE)
   Tell A Friend
 
Tell someone you know about this product.
   Reviews  more
 Write Review  Write a review on this product!
   Online Help
   Currencies

Copyright © 2011 Oceanpro Aquatics, Inc.

Customer Service: 909-233-6976
Mon-Wed 10am - 4pm PST
Thu-Fri (we are working on the fish farm and unable to answer the phone)
Sat-Sun & All Holidays (Closed)

Oceanpro Aquatics, Inc.
Southern California, USA

Shop Our Store | Free Catalog | VIP E-mail | Newsletter | Contact Us | Home

New Page 2

http://myaquariumshop.com/ Southern California's best quality Marine and Reef Tropical Fish, Reef Coral and Inverts.  Thousands Up to 85% OFF all aquarium products in our store located in Chino Hills, California, 91709.  Key Words http://www.OceanproAquatics.com/keywords_tropical_fish_coral.htm